57,439 research outputs found

    Magnets position X-ray film for weld inspection

    Get PDF
    Film-positioning device uses magnets to hold X ray film for weld inspection in nonferrous structures, such as tanks, where access to interior points is difficult

    Advanced infrared laser modulator development

    Get PDF
    A parametric study was conducted to develop an electrooptic waveguide modulator for generating continuous tunable sideband power from an infrared CO2 laser. Parameters included were the waveguide configurations, microstrip dimensions device impedance, and effective dielectric constants. An optimum infrared laser modulator was established and was fabricated. This modulator represents the state-of-the-art integrated optical device, which has a three-dimensional topology to accommodate three lambda/4 step transformers for microwave impedance matching at both the input and output terminals. A flat frequency response of the device over 20 HGz or = 3 dB) was achieved. Maximum single sideband to carrier power greater than 1.2% for 20 W microwave input power at optical carrier wavelength of 10.6 microns was obtained

    The drive system of the Major Atmospheric Gamma-ray Imaging Cherenkov Telescope

    Full text link
    The MAGIC telescope is an imaging atmospheric Cherenkov telescope, designed to observe very high energy gamma-rays while achieving a low energy threshold. One of the key science goals is fast follow-up of the enigmatic and short lived gamma-ray bursts. The drive system for the telescope has to meet two basic demands: (1) During normal observations, the 72-ton telescope has to be positioned accurately, and has to track a given sky position with high precision at a typical rotational speed in the order of one revolution per day. (2) For successfully observing GRB prompt emission and afterglows, it has to be powerful enough to position to an arbitrary point on the sky within a few ten seconds and commence normal tracking immediately thereafter. To meet these requirements, the implementation and realization of the drive system relies strongly on standard industry components to ensure robustness and reliability. In this paper, we describe the mechanical setup, the drive control and the calibration of the pointing, as well as present measurements of the accuracy of the system. We show that the drive system is mechanically able to operate the motors with an accuracy even better than the feedback values from the axes. In the context of future projects, envisaging telescope arrays comprising about 100 individual instruments, the robustness and scalability of the concept is emphasized.Comment: 15 pages, 12 (10) figures, submitted to Astroparticle Physics, a high resolution version of the paper (particularly fig. 1) is available at http://publications.mppmu.mpg.de/2008/MPP-2008-101/FullText.pd

    Inverter ratio failure detector

    Get PDF
    A failure detector which detects the failure of a dc to ac inverter is disclosed. The inverter under failureless conditions is characterized by a known linear relationship of its input and output voltages and by a known linear relationship of its input and output currents. The detector includes circuitry which is responsive to the detector's input and output voltages and which provides a failure-indicating signal only when the monitored output voltage is less by a selected factor, than the expected output voltage for the monitored input voltage, based on the known voltages' relationship. Similarly, the detector includes circuitry which is responsive to the input and output currents and provides a failure-indicating signal only when the input current exceeds by a selected factor the expected input current for the monitored output current based on the known currents' relationship

    An ``outside-in'' outburst of Aql X--1

    Get PDF
    We present optical spectroscopy and optical and infrared photometry of the neutron star soft X-ray transient Aql X--1 during its X-ray outburst of August 1997. By modelling the X-ray, optical, and IR light curves, we find a 3 day delay between the IR and X-ray rise times, analogous to the UV-optical delay seen in dwarf novae outbursts and black hole X-ray transients. We interpret this delay as the signature of an ``outside-in'' outburst, in which a thermal instability in the outer disc propagates inward. This outburst is the first of this type definitively identified in a neutron star X-ray transient.Comment: 6 pages latex, 2 figures, Accepted by MNRA

    A formal theory of cubical complexes Formal report, 1 Sep. 1968 - 30 Apr. 1969

    Get PDF
    Algorithm for computation of test failures in cyclic circuit

    Determination of gamma-ray widths in 15^{15}N using nuclear resonance fluorescence

    Full text link
    The stable nucleus 15^{15}N is the mirror of 15^{15}O, the bottleneck in the hydrogen burning CNO cycle. Most of the 15^{15}N level widths below the proton emission threshold are known from just one nuclear resonance fluorescence (NRF) measurement, with limited precision in some cases. A recent experiment with the AGATA demonstrator array determined level lifetimes using the Doppler Shift Attenuation Method (DSAM) in 15^{15}O. As a reference and for testing the method, level lifetimes in 15^{15}N have also been determined in the same experiment. The latest compilation of 15^{15}N level properties dates back to 1991. The limited precision in some cases in the compilation calls for a new measurement in order to enable a comparison to the AGATA demonstrator data. The widths of several 15^{15}N levels have been studied with the NRF method. The solid nitrogen compounds enriched in 15^{15}N have been irradiated with bremsstrahlung. The γ\gamma-rays following the deexcitation of the excited nuclear levels were detected with four HPGe detectors. Integrated photon-scattering cross sections of ten levels below the proton emission threshold have been measured. Partial gamma-ray widths of ground-state transitions were deduced and compared to the literature. The photon scattering cross sections of two levels above the proton emission threshold, but still below other particle emission energies have also been measured, and proton resonance strengths and proton widths were deduced. Gamma and proton widths consistent with the literature values were obtained, but with greatly improved precision.Comment: Final published version, minor grammar changes, 10 pages, 4 figures, 8 tables; An addendum is published where the last section is revised: T. Sz\"ucs and P. Mohr, Phys. Rev. C 92, 044328 (2015) [arXiv:1510.04956

    Axial compressor middle stage secondary flow study

    Get PDF
    This report describes an experimental investigation of the secondary flow within and aft of an axial compressor model with thick endwall boundary layers. The objective of the study was to obtain detailed aerodynamic and trace gas concentration traverse data aft of a well documented isolated rotor for the ultimate purpose of improving the design phases of compressor development based on an improved physical understanding of secondary flow. It was determined from the flow visualization, aerodynamic, and trace gas concentration results that the relative unloading of the midspan region of the airfoil inhibitied a fullspan separation at high loading preventing the massive radial displacement of the hub corner stall to the tip. Radial distribution of high and low total pressure fluid influenced the magnitude of the spanwise distribution of loss, such that, there was a general decreases in loss near the hub to the extent that for the least loaded case a negative loss (increase in total pressure) was observed. The ability to determine the spanwise distribution of blockage was demonstrated. Large blockage was present in the endwall regions due to the corner stall and tip leakage with little blockage in the core flow region. Hub blockage was found to increase rapidly with loading
    corecore